Continuous real-time oil condition analysis with 0.01% sensitivity, detecting and reporting changes caused by wear and or contamination.
Our unique molecular level analysis technology means that the smallest changes down to 100ppm are detected and reported in real time. This enables us reliably track oil wear and immediately detect contamination or equipment issues at the earliest stage
Can be fitted and used on any equipment type operating in any environment using any oil type - mineral or synthetic
Enables you to predict and pinpoint when equipment requires maintenance and oil is truly at the end of its life. This typically enables you to safely extend intervals between maintenance and reduce associated costs by approximately 30% per year
Unseen equipment issues cause subtle changes to oil condition, which are detected and alerted, enabling pre-emptive maintenance before failure or major damage and/or accelerated wear
Safely maximise oil use to reduce consumption by approximately 30% per annum. Reduce parts consumption and extend equipment life
Product Information
Name | Product Number |
---|---|
Gen 2 - Oil Quality Sensor | OQSxG2-1-XX-XX-5 |
Physical
Material | Dimensions | Weight | Connection | Torque |
---|---|---|---|---|
Stainless Steel AISI304 | 102mm x 36mm (L x W) | 180g | 32mm AF Hex Collar | 25N m |
Available Threads
Thread | Seal |
---|---|
1/2” BSPP | Dowty Type |
1/2” NPT | n/a |
7/8” UNF | ‘O’ Ring |
M18 | Dowty Type |
Connectors
Connector |
---|
6-Pin Bulgin PXP4013/06P/PC |
Electrical
Supply | Consumption |
---|---|
+9-30 V DC | 0.4w Average |
Data Output / Input
Digital Output | Protocols Supported | Analog Output |
---|---|---|
RS485, CANbus | Modbus, CanOpen and J1939 | 4-20mA |
Oil Quality Detection Parameters
Frequency | Output | Accuracy | Elements |
---|---|---|---|
Every 2 seconds | Tan Delta Number (TDN) | 0.01% | All wear and contamination |
Oil Temperature (°C or °F) |
Environmental
Operating Temperature | Calibrated Temperature | Fluid Temperature | Fluid Pressure | Storage Temperature |
---|---|---|---|---|
-40°C (-40°F) to +120°C (+248°F) | -20°C (-4°F) to +120°C (+248°F) | -40°C (-40°F) to +120°C (+248°F) | up to 70 bar (1015 psi) | -55°C (-67°F) to +150°C (+302°F) |
Standards & Certification
Water & Dust | Shock & Vibration | EMC | Conformity |
---|---|---|---|
IP68 when connected | BS EN 60068-2-30 (Test Db - Cyc.Hum.) | EN 61000-6-4:2007 (Generic Emissions Standard for Industrial Environments) | CE Marked |
BS EN 60068-2-6 (Test Fc - Sine Vib.) | EN 61000-6-2:2005 (Generic Immunity Standard for Industrial Environments) | EN 61000-6-2:2005 (Generic Immunity Standard for Industrial Environments) | |
BS EN 60068-2-27 (Test Ea - Mech.Shock) |
Chem-Tech® Laboratories is a leading provider of Testing, Consultancy & Certification services in the area of industrial products and consumables.
Chem-Tech® Laboratories is a leading provider of Testing, Consultancy & Certification services in the area of industrial products and consumables.
If you have any questions or need help, feel free to contact with our team.