Condition Monitoring Sensor

The information gathered can help confirm the cause of health concerns or rule out any potential concerns which are a critical tools in helping healthcare providers understand.

Condition Monitoring Sensor

Real time oil condition analysis sensor with integrated intelligent equipment maintenance optimisation analytics for all industrial and commercial applications.

OQSx-G2 delivers the ultimate high-quality real-time oil condition analysis. This enables multiple tangible operating benefits that include reduced maintenance costs, improved reliability, reduced oil wastage, and extended equipment life.

Our unique FSH™ core technology analyses oil condition holistically, detecting, measuring and tracking all and any contamination or wear with 0.01% sensitivity (100ppm) – other sensor systems typically look at specific parameters and ignore others. This unmatched real-time complete oil analysis capability is achieved through continuous analysis of the electro-chemical properties of the oil at a molecular level.

OQSx-G2 analysis data provides unrivalled high-confidence insight into real-time equipment health and maintenance status. Reliable forecasting and planning of maintenance based upon actual equipment need and thus extended optimised maintenance intervals and reduced cost becomes possible; with the assurance and safety of continuous over-watch that detects any unexpected anomalies and or contamination.

OQSx-G2 works with any oil type and is easily fitted to any equipment operating in any environment or application.
  • REAL TIME ANALYSIS

    Continuous real-time oil condition analysis with 0.01% sensitivity, detecting and reporting changes caused by wear and or contamination.

  • RELIABLE ACCURACY

    Our unique molecular level analysis technology means that the smallest changes down to 100ppm are detected and reported in real time. This enables us reliably track oil wear and immediately detect contamination or equipment issues at the earliest stage

  • ANY OIL TYPE AND EQUIPMENT

    Can be fitted and used on any equipment type operating in any environment using any oil type - mineral or synthetic

  • REDUCE MAINTENANCE COSTS

    Enables you to predict and pinpoint when equipment requires maintenance and oil is truly at the end of its life. This typically enables you to safely extend intervals between maintenance and reduce associated costs by approximately 30% per year

  • REDUCED DOWNTIME

    Unseen equipment issues cause subtle changes to oil condition, which are detected and alerted, enabling pre-emptive maintenance before failure or major damage and/or accelerated wear

  • ENVIRONMENTAL (ESG) TARGETS

    Safely maximise oil use to reduce consumption by approximately 30% per annum. Reduce parts consumption and extend equipment life

OQSx-G2-663x408
OQSx-G2-Dims-1-663x408

Technical Specifications

Product Information

Name Product Number
Gen 2 - Oil Quality Sensor
OQSxG2-1-XX-XX-5

Physical

Material Dimensions Weight Connection Torque
Stainless Steel AISI304
102mm x 36mm (L x W)
180g
32mm AF Hex Collar
25N m

Available Threads

Thread Seal

1/2” BSPP



1/2” NPT



7/8” UNF



M18



Dowty Type



n/a



‘O’ Ring



Dowty Type


Connectors

Connector

6-Pin Bulgin PXP4013/06P/PC

Electrical

Supply Consumption

+9-30 V DC

0.4w Average

Data Output / Input

Digital Output Protocols Supported Analog Output

RS485, CANbus

Modbus, CanOpen and J1939

4-20mA

Oil Quality Detection Parameters

Frequency Output Accuracy Elements

Every 2 seconds

Tan Delta Number (TDN)



Oil Temperature (°C or °F))

0.01%

All wear and contamination

Environmental

Operating Temperature Calibrated Temperature Fluid Temperature Fluid Pressure Storage Temperature

-40°C (-40°F) to

+120°C (+248°F)

-20°C (-4°F) to

+120°C (+248°F)

-40°C (-40°F) to

+120°C (+248°F)

up to 70 bar

(1015 psi)

-55°C (-67°F) to

+150°C (+302°F)

Standards & Certification

Water & Dust Shock & Vibration EMC Conformity

IP68 when connected

BS EN 60068-2-30 (Test Db - Cyc.Hum.)



BS EN 60068-2-6 (Test Fc - Sine Vib.)



BS EN 60068-2-27 (Test Ea - Mech.Shock)


EN 61000-6-4:2007 (Generic Emissions Standard for Industrial Environments)



EN 61000-6-2:2005 (Generic Immunity Standard for Industrial Environments)


CE Marked




EN 61000-6-2:2005 (Generic Immunity Standard for Industrial Environments)


en_USEnglish