Chem-Tech technical resource

Laboratory Test List

Review published tests, analytical methods, technical purpose and interpretation context across Chem-Tech service divisions.

Filter published capability

Search tests and methods

Search Chem-Tech's published test list by parameter, method, purpose or interpretation.

Search the laboratory test list

248 published test entries across 17 service groups

Lubricants & fluids

Lubricating oils

Physical, chemical, contamination and condition-monitoring parameters for fresh and in-service lubricants.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
AppearanceCTP T 112Records the visible condition and colour of the submitted sample.Unexpected haze, sediment, separation or colour change may indicate contamination, degradation or sample-handling effects; compare with the product reference.Inhouse
Density / Specific GravityASTM D1298 / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Kinematic ViscosityASTM D445 / ASTM D7042Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Viscosity IndexASTM D2270Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Water ContentASTM E203 / ASTM D1744 / ASTM D6304Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Flash & Fire Point (COC)ASTM D92Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Total Base NumberASTM D4739 / ASTM D2896Measures reserve alkalinity in applicable lubricants.A lower result relative to fresh oil or trend data may indicate reserve depletion; an unexpectedly high value may indicate a different formulation or mixing.Inhouse
Total Acid NumberASTM D664 / ASTM D974Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Elemental Analysis by ICPASTM D5185 / ASTM D4951Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Particle Count / CleanlinessNAS 1638 / ISO 4406Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Foaming Tendency & StabilityASTM D892Assesses foam tendency and, where applicable, foam stability.Higher foam volume or persistence may indicate poorer air-release behaviour, contamination or additive-related change under the test conditions.Inhouse
Water SeparabilityASTM D1401Assesses separation behaviour between oil and water.Longer separation time or persistent emulsion may indicate reduced water-separation performance; compare with the applicable product requirement.Inhouse
Soot ContentASTM D7686Measures combustion-derived soot in used engine oil.A higher result indicates greater soot loading and should be reviewed with engine condition, oil hours and viscosity change.Inhouse
Fuel DilutionASTM D7593Assesses fuel contamination in used engine oil.A higher result indicates more fuel in the lubricant and may be associated with viscosity reduction; operating information is needed for diagnosis.Inhouse
PQ IndexASTM D8184Measures or evaluates pq index under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
FTIR Condition MonitoringASTM E2412Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Pour PointASTM D97Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Sulphur ContentASTM D4294Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Ash ContentASTM D482Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Conradson Carbon ResidueASTM D189Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
InsolublesASTM D893Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Saponification ValueASTM D94Measures or evaluates saponification value under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Analytical FerrographyASTM D7690Measures or evaluates analytical ferrography under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Cooling Curve AnalysisASTM D6200Measures or evaluates cooling curve analysis under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Distillation Recovery / Initial Boiling PointASTM D86Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse

Lubricants & fluids

Grease

Composition, consistency, stability, corrosion and load-carrying characteristics for lubricating greases.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Soap or Thickener TypeICP-OESMeasures or evaluates soap or thickener type under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Base Oil Viscosity at 40 °CASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Drop PointASTM D566Measures or evaluates drop point under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Worked Cone Penetration - 60 StrokesASTM D217Measures or evaluates worked cone penetration - 60 strokes under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Worked Cone Penetration - Extended WorkingASTM D217Measures or evaluates worked cone penetration - extended working under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Copper CorrosionASTM D4048Measures or evaluates copper corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Water ContentASTM D95 / ASTM D1744Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Elemental Analysis by ICPASTM D7303Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Water Washout CharacteristicsASTM D1264Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Oil SeparationIP 121 / ASTM D1742Measures or evaluates oil separation under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Storage StabilityASTM D1742Measures or evaluates storage stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Heat StabilityASTM D6184Measures or evaluates heat stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Roll StabilityASTM D1831Measures or evaluates roll stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Wheel Bearing Leakage TendencyASTM D1263Measures or evaluates wheel bearing leakage tendency under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Four Ball Weld LoadASTM D2596Measures or evaluates four ball weld load under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Four Ball Wear Scar DiameterASTM D2266Measures or evaluates four ball wear scar diameter under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Emcor Rust TestASTM D6138Measures or evaluates emcor rust test under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Oxidation StabilityASTM D942Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Corrosion Preventive CharacteristicsASTM D1743Measures or evaluates corrosion preventive characteristics under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Lubricants & fluids

Metalworking fluids

Condition, concentration, contamination and performance-related tests for neat and water-miscible fluids.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Kinematic Viscosity at 40 °C and 100 °CASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Viscosity IndexASTM D2270Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Total Acid NumberASTM D664Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Flash PointASTM D92Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Moisture ContentASTM D95Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
i-pH ValueASTM D7946Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
Sulphur ContentASTM D4294Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Elemental AnalysisASTM D5185Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Copper Strip CorrosionASTM D130Measures or evaluates copper strip corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Rust TestASTM D665Measures or evaluates rust test under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Chlorine ContentASTM D4929Measures or evaluates chlorine content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
SedimentsASTM D4055Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
FerrographyASTM D7680Measures or evaluates ferrography under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Particle CountISO 4406 / NAS 1638Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
pHpH MeterMeasures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
Tramp OilAcid SplitMeasures or evaluates tramp oil under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
ConcentrationAcid Split / RefractometerMeasures or evaluates concentration under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Bacteria CountKit MethodAssesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
HardnessTitrationMeasures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
ConductivityConductivity MeterAssesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse

Lubricants & fluids

Quenching oil

Condition and heat-treatment performance indicators for fresh and in-service quenching oils.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Cooling Analysis CurveASTM D6200Measures or evaluates cooling analysis curve under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Kinematic Viscosity at 40 °C and 100 °CASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Viscosity IndexASTM D2270Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Volatile Matter at 210 °C for 2 HoursCTPMeasures or evaluates volatile matter at 210 °c for 2 hours under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Saponification NumberASTM D94Measures or evaluates saponification number under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total Acid NumberASTM D664Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Precipitation NumberASTM D91Measures or evaluates precipitation number under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Moisture ContentASTM D95Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Flash PointASTM D92Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
pH ValueASTM D1287Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse

Lubricants & fluids

Thermic fluid

Thermal-degradation, volatility, acidity and contamination indicators for heat-transfer fluids.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Specific Gravity or Density at 15 °CASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Kinematic Viscosity at 40 °CASTM D7042Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Kinematic Viscosity at 100 °CASTM D7042Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Viscosity IndexASTM D2270Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Ash ContentASTM D482Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Total Acid NumberASTM D664Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Flash and Fire Point - COCASTM D92Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Conradson Carbon ResidueASTM D189Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
Insoluble in HexaneASTM D893Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Insoluble in TolueneASTM D893Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Distillation Recovery / Initial Boiling PointASTM D86Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse
Water Content - PotentiometricASTM E203Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse

Lubricants & fluids

Coolant

Chemical condition, freeze/boil protection, corrosion-related elements and contamination indicators.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
ColourCTP T112Records the visible condition and colour of the submitted sample.Unexpected haze, sediment, separation or colour change may indicate contamination, degradation or sample-handling effects; compare with the product reference.Inhouse
pHASTM D1287Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
Total Dissolved SolidsCTP T093Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Chloride ContentASTM D3634Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Sulphate ContentASTM D5827Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Nitrate ContentASTM D5827Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Total HardnessCTP T164Measures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
ConductivityCTP T144Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Elemental Analysis - Wear and Corrosion MetalsASTM D6130Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Reserve AlkalinityASTM D1121Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Foaming TendencyASTM D1881Assesses foam tendency and, where applicable, foam stability.Higher foam volume or persistence may indicate poorer air-release behaviour, contamination or additive-related change under the test conditions.Inhouse
Equilibrium Reflux Boiling PointASTM D1120Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse
Freezing PointASTM D3321Measures or evaluates freezing point under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Water ContentASTM E203Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Glycol ContentRefractometerMeasures or evaluates glycol content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Oxalate, Formate and Inorganic IonsASTM D5827Measures or evaluates oxalate, formate and inorganic ions under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Lubricants & fluids

AdBlue / diesel exhaust fluid

Identity, urea concentration and impurity-related parameters aligned with the published AdBlue capability.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Urea ContentISO 22241-2 Annex CMeasures or evaluates urea content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Refractive IndexISO 22241-2 Annex CMeasures or evaluates refractive index under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Alkalinity as NH₃ISO 22241-2 Annex DReports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
BiuretISO 22241-2 Annex EMeasures or evaluates biuret under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
AldehydesISO 22241-2 Annex FMeasures or evaluates aldehydes under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
PhosphateISO 22241-2 Annex HMeasures or evaluates phosphate under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
IdentityISO 22241-2 Annex JMeasures or evaluates identity under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Fuels & solid fuels

Diesel fuel

Specification, combustion, low-temperature, contamination and handling-safety parameters for diesel fuels.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Inorganic AcidityIS 1448 (P2)Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Total AcidityIS 1448 (P2)Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Ash ContentASTM D482 / IS 1448 (P4)Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Ramsbottom Carbon ResidueASTM D524 / IS 1448 (P8)Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
Cetane IndexASTM D4737Measures or evaluates cetane index under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Pour PointASTM D97 / IS 1448 (P10)Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Copper Strip CorrosionASTM D130 / IS 1448 (P15)Measures or evaluates copper strip corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Distillation Recovery with IBP / FBPASTM D86 / IS 1448 (P18)Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse
Flash Point - AbelIS 1448 (P20)Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Kinematic Viscosity at 40 °CASTM D445 / ASTM D7042 / IS 1448 (P25)Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Sediment by ExtractionASTM D473 / IS 1448 (P30)Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Density / Specific GravityASTM D1298 / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Total SulphurASTM D4294 / ASTM D5453Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Water ContentASTM D6304 / ISO 12937Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Cold Filter Plugging PointASTM D6371 / IS 1448 (P110)Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Lubricity - Wear Scar DiameterASTM D6079Measures or evaluates lubricity - wear scar diameter under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Gross Calorific ValueASTM D240 / IS 1448 (P6)Measures the heat released during controlled combustion.A higher value indicates greater energy content per reported basis; a lower value may reflect moisture, ash or material-composition differences.Inhouse
Chlorine ContentASTM D4929Measures or evaluates chlorine content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
CleanlinessISO 4406Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Oxidation StabilityASTM D2274Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Total ContaminationEN 12662Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Cloud PointASTM D2500Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse

Fuels & solid fuels

Biodiesel

Fuel-property, ester-content, stability, contamination and specification-related biodiesel parameters.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Density / Specific GravityASTM D1298 / ASTM D4052 / ISO 12185Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Kinematic Viscosity at 40 °CASTM D445 / ASTM D7042 / ISO 3104Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Carbon Residue - RBCRASTM D524 / ISO 10370Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
Sulphur ContentASTM D4294Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Sulphated AshASTM D874 / ISO 3987Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Water ContentASTM D6304 / ISO 12937Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Sediments by CentrifugeChem-Tech Test ListAssesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Copper Strip CorrosionASTM D130 / ISO 2160Measures or evaluates copper strip corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total Acid NumberASTM D664Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
Total ContaminationEN 12662Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Ester / FAME ContentEN 14103Measures or evaluates ester / fame content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Phosphorus and Alkali MetalsASTM D7111Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Iodine ValueEN 14104Measures or evaluates iodine value under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Gross Calorific ValueASTM D240Measures the heat released during controlled combustion.A higher value indicates greater energy content per reported basis; a lower value may reflect moisture, ash or material-composition differences.Inhouse
Flash Point - PMCCASTM D93Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Oxidation StabilityEN 14112Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Methanol and Ethanol ContentEN 14110Measures or evaluates methanol and ethanol content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Total and Free GlycerolASTM D6584Measures or evaluates total and free glycerol under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced

Fuels & solid fuels

Bunker and marine fuel

Marine-fuel quality, ignition-related, contamination, stability and handling parameters.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
DensityISO 3675 / ISO 12185 / ASTM D1298 / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Kinematic ViscosityISO 3104 / ASTM D445 / ASTM D7042Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Flash Point - Pensky-MartensISO 2719 / ASTM D93Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Cloud PointISO 3015 / ASTM D2500Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Pour PointISO 3016 / ASTM D97Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Water ContentISO 3733 / ASTM D95Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Cetane IndexISO 4264Measures or evaluates cetane index under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Ash ContentISO 6245 / ASTM D482Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Sulphur ContentISO 8754 / ASTM D4294Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Total SedimentISO 10307-1Assesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
Carbon ResidueISO 10370Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
Lubricity - HFRRASTM D6078Measures or evaluates lubricity - hfrr under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Oxidation StabilityISO 12205 / ASTM D2274Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Water Content - Karl FischerISO 12937 / ASTM D1744Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Elemental AnalysisIP 470Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Acid NumberASTM D664Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse

Fuels & solid fuels

Furnace oil

Viscosity, combustion value, residue, water, sulphur and handling characteristics for furnace oil.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Density at 15 °CIS 1448 (P32) / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Kinematic Viscosity at 50 °CIS 1448 (P25) / ASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Kinematic Viscosity at 100 °CIS 1448 (P25) / ASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Flash Point - PMCCIS 1448 (P21) / ASTM D93Determines the temperature at which vapour ignites under the selected procedure.A lower result may indicate volatile contamination or product change; a higher result is interpreted against the identified grade and method.Inhouse
Water Content - Dean and StarkIS 1448 (P40) / ASTM D95Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Ash ContentIS 1448 (P4) / ASTM D482Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Conradson Carbon ResidueIS 1448 (P122) / ASTM D189Assesses the tendency to leave carbonaceous residue under the selected procedure.A higher result indicates greater residue-forming tendency; relevance depends on the fuel grade and application.Inhouse
Inorganic AcidityIS 1448 (P2)Measures acidic constituents under the selected method.An increase from the reference may support oxidation or acidic-contamination review; a single result must be compared with product and service history.Inhouse
SedimentsCTPAssesses particulate, sediment or insoluble contamination in the sample.A higher result indicates more suspended or insoluble material; acceptability depends on the equipment, product specification and sampling point.Inhouse
AsphaltenesIS 1448 (P22) / ASTM D6560Measures or evaluates asphaltenes under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Metal ContentIP 501Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Pour PointIS 1448 (P10 Sec 2) / ASTM D97Assesses low-temperature flow or operability characteristics.A higher temperature generally indicates poorer low-temperature behaviour; compare with the climatic and product requirement.Inhouse
Gross Calorific ValueIS 1448 (P6) / ASTM D240Measures the heat released during controlled combustion.A higher value indicates greater energy content per reported basis; a lower value may reflect moisture, ash or material-composition differences.Inhouse
Net Calorific ValueIS 1448 (P6)Measures the heat released during controlled combustion.A higher value indicates greater energy content per reported basis; a lower value may reflect moisture, ash or material-composition differences.Inhouse
Sulphur ContentIS 1448 (P33) / ASTM D4294Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Hydrogen ContentIS 1448 (P6) / CalculationMeasures or evaluates hydrogen content under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Fuels & solid fuels

Gasoline

Core published fuel-property checks relevant to gasoline quality investigations.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Copper Strip CorrosionASTM D130 / IS 1448 (P15)Measures or evaluates copper strip corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Distillation Recovery with IBP / FBPASTM D86 / IS 1448 (P18)Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse
Density / Specific GravityASTM D1298 / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Total SulphurASTM D4294 / ASTM D5453Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Water ContentASTM D6304 / ISO 12937Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse

Fuels & solid fuels

Aviation turbine fuel

Core published fuel-property checks used when defining an aviation-fuel testing requirement.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Copper Strip CorrosionASTM D130 / IS 1448 (P15)Measures or evaluates copper strip corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Distillation Recovery with IBP / FBPASTM D86 / IS 1448 (P18)Characterises volatility and recovery across the boiling range.Higher or lower recovery temperatures may indicate composition change, contamination or a different product grade when compared with the applicable specification.Inhouse
Density / Specific GravityASTM D1298 / ASTM D4052Measures mass per unit volume and supports product identification or specification review.A result above or below the applicable range may indicate product mixing, contamination, composition change or an incorrect grade.Inhouse
Total SulphurASTM D4294 / ASTM D5453Quantifies sulphur in the submitted fuel or material.A higher result may affect specification compliance, emissions-related requirements or process suitability; compare with the identified grade.Inhouse
Water ContentASTM D6304 / ISO 12937Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse

Fuels & solid fuels

Coal and briquette

Solid-fuel scope is confirmed against the sample type, customer objective and applicable specification.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List

A controlled test-to-method mapping for coal and briquette is awaiting Chem-Tech technical confirmation and is therefore not published here.

Food & water

Food and agricultural products

Physicochemical, nutritional and microbiological parameters selected according to the submitted food matrix.
Source: Food, Food Products and Water Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
MoistureApplicable FSSAI / IS method by food matrixQuantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
pHApplicable FSSAI method by food matrixMeasures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
AcidityApplicable FSSAI / IS method by food matrixMeasures or evaluates acidity under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total SolidsApplicable FSSAI method by food matrixMeasures or evaluates total solids under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total AshApplicable FSSAI / IS method by food matrixMeasures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Total FatApplicable FSSAI / IS method by food matrixMeasures or evaluates total fat under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total ProteinApplicable FSSAI / IS method by food matrixMeasures or evaluates total protein under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
CarbohydratesCalculation / applicable source methodMeasures or evaluates carbohydrates under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
EnergyCalculation / applicable source methodMeasures or evaluates energy under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Total, Natural and Added SugarApplicable FSSAI / SOP method by food matrixMeasures or evaluates total, natural and added sugar under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Vitamins A, D, E, K and CChem-Tech SOPMeasures or evaluates vitamins a, d, e, k and c under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Benzoic AcidChem-Tech SOPMeasures or evaluates benzoic acid under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Sorbic AcidChem-Tech SOPMeasures or evaluates sorbic acid under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
AspartameChem-Tech SOPMeasures or evaluates aspartame under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
SaccharinChem-Tech SOPMeasures or evaluates saccharin under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
AcesulfameChem-Tech SOPMeasures or evaluates acesulfame under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Aerobic Plate CountIS 5402Measures or evaluates aerobic plate count under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
E. coliIS 5887 Part IAssesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
ColiformIS 5401Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
Staphylococcus aureusIS 5887 Part IIMeasures or evaluates staphylococcus aureus under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Yeast and MouldIS 5403Measures or evaluates yeast and mould under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
ShigellaIS 5887 Part VIIMeasures or evaluates shigella under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Food & water

Water

Physical, chemical, organic-load and microbiological parameters for drinking, process and waste water.
Source: Food, Food Products and Water Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
AppearanceAPHA 2110:2017 / CTP-T-112Records the visible condition and colour of the submitted sample.Unexpected haze, sediment, separation or colour change may indicate contamination, degradation or sample-handling effects; compare with the product reference.Inhouse
Elemental AnalysisASTM D1976 / CTP-T-125Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Ammonia / Ammoniacal NitrogenAPHA 4500-NH3-C / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
NitrateAPHA 4500-NO3-B / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
NitriteAPHA 4500-NO2-B / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
CalciumAPHA 3500-Ca-BMeasures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
Total HardnessAPHA 2340-B,C / IS 3025 Part 21Measures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
ChlorideAPHA 4500-Cl-B,D / IS 3025 Part 32Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
ConductivityAPHA 2510-B / IS 3025 Part 14Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Dissolved OxygenAPHA 4500-O-B,C / IS 3025 Part 38Measures oxygen dissolved in the water sample.Lower values may indicate oxygen demand or limited aeration; higher values reflect greater oxygen availability under the sampling conditions.Inhouse
FluorideAPHA 4500-F-D / IS 3025 Part 60Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Free Residual ChlorineAPHA 4500-Cl-B / IS 3025 Part 26Measures disinfectant residual present at the sampling point.A low result may indicate insufficient residual, while a high result may affect acceptability or process use; compare with the applicable requirement.Inhouse
Oil and GreaseAPHA 5520-B:2017 / IS 3025 Part 39Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
pHAPHA 4500-H+-B / IS 3025 Part 11Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
SulphateAPHA 4500-SO4-E / IS 3025 Part 24Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Total AlkalinityAPHA 2320-B / IS 3025 Part 23Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Total Dissolved SolidsAPHA 2540-C / IS 3025 Part 16Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Total Suspended SolidsAPHA 2540-D / IS 3025 Part 17Assesses suspended material or optical cloudiness in water.A higher result indicates more suspended or light-scattering material and may signal inadequate clarification, contamination or process carryover.Inhouse
TurbidityAPHA 2130-B / IS 3025 Part 10Assesses suspended material or optical cloudiness in water.A higher result indicates more suspended or light-scattering material and may signal inadequate clarification, contamination or process carryover.Inhouse
Biochemical Oxygen DemandIS 3025 Part 44Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
Chemical Oxygen DemandIS 3025 Part 58Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
Microbial ExaminationIS 1622Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
Total and Faecal ColiformIS 5401 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
E. coliIS 5887 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
Total Organic CarbonAPHA 23rd Edition 5310BAssesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse

Product compliance

Product compliance

Restricted-substance parameters and published IEC methods for product-compliance investigations.
Source: Product Compliance Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Lead (Pb)IEC 62321-5:2013 / IEC 62321-3:2013 (XRF)Measures or evaluates lead (pb) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Cadmium (Cd)IEC 62321-5:2013 / IEC 62321-3:2013 (XRF)Measures or evaluates cadmium (cd) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Mercury (Hg)IEC 62321-4:2017 / IEC 62321-3:2017 (XRF)Measures or evaluates mercury (hg) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Hexavalent Chromium (CrVI)IEC 62321-7-2:2017 / IEC 62321-3:2017 (XRF)Measures or evaluates hexavalent chromium (crvi) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Polybrominated Biphenyls (PBB)IEC 62321-6:2015Measures or evaluates polybrominated biphenyls (pbb) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Polybrominated Diphenyl Ethers (PBDE)IEC 62321-6:2015Measures or evaluates polybrominated diphenyl ethers (pbde) under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
DEHPIEC 62321-8:2015Measures or evaluates dehp under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
BBPIEC 62321-8:2015Measures or evaluates bbp under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
DBPIEC 62321-8:2015Measures or evaluates dbp under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
DIBPIEC 62321-8:2015Measures or evaluates dibp under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Need a test not shown here?

Ask the laboratory to review your requirement.

Request a QuoteContact Chem-Tech →