Indian water-testing professional collecting a clear drinking-water sample

Drinking water analysis | Drinking water testing

Drinking Water Testing

India-wide drinking water testing coordinated in Pune, Maharashtra. Confirm the sample, scope and reporting requirement with Chem-Tech.

Get A Quote

Overview

What is drinking water testing?

Chem-Tech Laboratories provides drinking-water analysis for defined product, process and use requirements. The available method, sample handling and reporting scope are confirmed for the identified water source.

Indian water-testing professional collecting a clear drinking-water sample

Water-use context

Drinking-water sources and applications

  • laboratory facilities:

  • Experienced Team:

  • Regulatory Compliance:

  • Timely Reporting:

  • Customized Solutions:

Drinking Water as per ISO 10500 :

Chem-Tech Laboratories Ensure the purity and safety of your drinking water with our IS 10500 compliant water testing services. Our rigorous analysis covers pH levels, turbidity, microbial contamination, chemical pollutants, heavy metals, and more. Trust us to provide reliable results and help you meet regulatory requirements.

Packaged Drinking Water as per ISO 14543 :

Chem-Tech Laboratories Comply with IS 14543 standards for packaged drinking water with our comprehensive testing services. We assess microbiological safety, chemical composition, residual chlorine levels, total dissolved solids (TDS), and other crucial quality indicators. Maintain the highest standards of quality for your packaged drinking water products.

Swimming Pool Water/Spa Water as per ISO 332 :

Chem-Tech Laboratories Create a healthy and safe environment for swimmers with our water testing services aligned with IS 332 guidelines. We identify risks related to bacterial contamination, pH imbalance, disinfectant levels, and other factors affecting water quality in swimming pools and spas. Trust our expertise for reliable results.

Industrial Cooling Water Testing :

Chem-Tech Laboratories Ensure efficient and reliable industrial cooling systems with our comprehensive testing services. Our analysis includes pH, hardness, corrosion levels, microbial activity, scaling potential, and contaminant presence assessment. Rely on us to maintain optimal operating conditions for your industrial processes.

Packaged Mineral Drinking Water as per ISO 13428 :

Chem-Tech Laboratories Comply with IS 13428 standards for packaged mineral drinking water with our specialized testing services. We analyze mineral content, pH levels, microbial safety, chemical composition, and taste profile to ensure your products meet the highest quality and purity standards. Trust us for reliable results and compliance.

Water for Food Processing Industry as per ISO 4251 :

Chem-Tech Laboratories Maintain food safety and hygiene standards with our water testing services designed for the food processing industry as per IS 4251 guidelines. We evaluate microbiological contamination, chemical pollutants, organoleptic properties, and regulatory compliance to ensure the suitability of water in food processing applications.

Technical review

Common water-quality and contamination concerns

pH and mineral balance

pH, alkalinity, hardness and dissolved-ion results are reviewed together with the water source and intended use.

Dissolved and suspended material

Dissolved solids, suspended solids and turbidity support review of clarity, treatment and process-related concerns.

Microbiological condition

Microbiological parameters are selected for the water use, sampling point and applicable requirement.

Requirement and sampling context

Interpretation depends on the identified standard, representative sampling, preservation and the time between collection and testing.

Published laboratory capability

Tests and test methods

The methods below are matched to Chem-Tech's controlled technical test lists and published laboratory capability. The final scope is confirmed for the sample, specification and current laboratory capability.

Test / parameterPublished test methodTechnical purposeInterpretation / high-low context
AppearanceAPHA 2110:2017 / CTP-T-112Records the visible condition and colour of the submitted sample.Unexpected haze, sediment, separation or colour change may indicate contamination, degradation or sample-handling effects; compare with the product reference.
Elemental AnalysisASTM D1976 / CTP-T-125Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.
NitrateAPHA 4500-NO3-B / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.
CalciumAPHA 3500-Ca-BMeasures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.
Total HardnessAPHA 2340-B,C / IS 3025 Part 21Measures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.
ChlorideAPHA 4500-Cl-B,D / IS 3025 Part 32Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.
ConductivityAPHA 2510-B / IS 3025 Part 14Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.
FluorideAPHA 4500-F-D / IS 3025 Part 60Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.
Free Residual ChlorineAPHA 4500-Cl-B / IS 3025 Part 26Measures disinfectant residual present at the sampling point.A low result may indicate insufficient residual, while a high result may affect acceptability or process use; compare with the applicable requirement.
pHAPHA 4500-H+-B / IS 3025 Part 11Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.
SulphateAPHA 4500-SO4-E / IS 3025 Part 24Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.
Total AlkalinityAPHA 2320-B / IS 3025 Part 23Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.
Total Dissolved SolidsAPHA 2540-C / IS 3025 Part 16Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.
TurbidityAPHA 2130-B / IS 3025 Part 10Assesses suspended material or optical cloudiness in water.A higher result indicates more suspended or light-scattering material and may signal inadequate clarification, contamination or process carryover.
Microbial ExaminationIS 1622Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.
Total and Faecal ColiformIS 5401 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.
E. coliIS 5887 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.

View the complete applicable test list

Before dispatch

Sample-submission guidance

  • Use a clean, secure and appropriately labelled container.
  • Provide the sample identity, fluid grade and equipment or system details where applicable.
  • Share operating hours, maintenance history, the suspected problem and required specification where available.
  • Contact Chem-Tech before dispatch so the laboratory can confirm the sample quantity, container and selected testing scope.

Technical output

Reporting and interpretation

The report records results and methods for the agreed scope. Customer-supplied limits or specifications can be considered when provided before testing.

Results should be reviewed with equipment history, operating conditions and previous data; a laboratory result alone does not guarantee a root-cause diagnosis or remaining service life.

Discuss your requirement

Need more information?

Share the water source, intended use and testing objective with the Chem-Tech team.