Chem-Tech technical resource

Laboratory Test List, Parameters and Methods

Search Chem-Tech's published laboratory tests by sample type, parameter, method, purpose and reporting context, then request the appropriate scope.

Search the laboratory test list

Laboratory capability finder

Published Test Catalogue

Explore commonly requested laboratory tests by service division. Capability listings and NABL accreditation are presented separately to avoid implying accreditation where it does not apply.

19 published test entries across 1 service groups.

Lubricants & fluids

Grease

Composition, consistency, stability, corrosion and load-carrying characteristics for lubricating greases.
Source: Petroleum Products, Lubricants, Fuels, Coolant and AdBlue Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
Soap or Thickener TypeICP-OESMeasures or evaluates soap or thickener type under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Base Oil Viscosity at 40 °CASTM D445Characterises resistance to flow and, where applicable, viscosity response to temperature.Higher viscosity may accompany oxidation, soot or heavier-product contamination; lower viscosity may accompany dilution, shear or lighter-product mixing.Inhouse
Drop PointASTM D566Measures or evaluates drop point under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Worked Cone Penetration - 60 StrokesASTM D217Measures or evaluates worked cone penetration - 60 strokes under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Worked Cone Penetration - Extended WorkingASTM D217Measures or evaluates worked cone penetration - extended working under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Copper CorrosionASTM D4048Measures or evaluates copper corrosion under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Water ContentASTM D95 / ASTM D1744Quantifies water or moisture in the submitted material.A higher result may indicate ingress, condensation, storage or handling contamination; significance depends on the product and applicable limit.Inhouse
Elemental Analysis by ICPASTM D7303Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Water Washout CharacteristicsASTM D1264Measures non-combustible residue remaining after controlled combustion.A higher result indicates more inorganic residue and may affect fuel quality, deposits or specification compliance.Inhouse
Oil SeparationIP 121 / ASTM D1742Measures or evaluates oil separation under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Storage StabilityASTM D1742Measures or evaluates storage stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Heat StabilityASTM D6184Measures or evaluates heat stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Roll StabilityASTM D1831Measures or evaluates roll stability under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Wheel Bearing Leakage TendencyASTM D1263Measures or evaluates wheel bearing leakage tendency under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Outsourced
Four Ball Weld LoadASTM D2596Measures or evaluates four ball weld load under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Four Ball Wear Scar DiameterASTM D2266Measures or evaluates four ball wear scar diameter under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Emcor Rust TestASTM D6138Measures or evaluates emcor rust test under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse
Oxidation StabilityASTM D942Assesses oxidation stability or condition-related spectral indicators.Greater oxidation-related change may indicate degradation; stability results and spectral trends must be interpreted using the applicable method and reference.Inhouse
Corrosion Preventive CharacteristicsASTM D1743Measures or evaluates corrosion preventive characteristics under the published method.A higher or lower result is interpreted against the applicable specification, sample type and available reference data; direction alone does not establish conformity.Inhouse

Need a test not shown here?

Ask the laboratory to review your requirement.

Request a QuotePetroleum products testing →Contact Chem-Tech →