Chem-Tech technical resource

Laboratory Test List

Review published tests, analytical methods, technical purpose and interpretation context across Chem-Tech service divisions.

Search the laboratory test list

25 published test entries across 1 service groups

Food & water

Water

Physical, chemical, organic-load and microbiological parameters for drinking, process and waste water.
Source: Food, Food Products and Water Test List
Test / parameterPublished methodTechnical purposeInterpretation contextCapability
AppearanceAPHA 2110:2017 / CTP-T-112Records the visible condition and colour of the submitted sample.Unexpected haze, sediment, separation or colour change may indicate contamination, degradation or sample-handling effects; compare with the product reference.Inhouse
Elemental AnalysisASTM D1976 / CTP-T-125Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Ammonia / Ammoniacal NitrogenAPHA 4500-NH3-C / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
NitrateAPHA 4500-NO3-B / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
NitriteAPHA 4500-NO2-B / IS 3025 Part 34Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
CalciumAPHA 3500-Ca-BMeasures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
Total HardnessAPHA 2340-B,C / IS 3025 Part 21Measures hardness-forming minerals or their contributing ions.Higher values can increase scaling tendency; very low values may be relevant to corrosivity or treatment control depending on the application.Inhouse
ChlorideAPHA 4500-Cl-B,D / IS 3025 Part 32Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
ConductivityAPHA 2510-B / IS 3025 Part 14Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Dissolved OxygenAPHA 4500-O-B,C / IS 3025 Part 38Measures oxygen dissolved in the water sample.Lower values may indicate oxygen demand or limited aeration; higher values reflect greater oxygen availability under the sampling conditions.Inhouse
FluorideAPHA 4500-F-D / IS 3025 Part 60Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Free Residual ChlorineAPHA 4500-Cl-B / IS 3025 Part 26Measures disinfectant residual present at the sampling point.A low result may indicate insufficient residual, while a high result may affect acceptability or process use; compare with the applicable requirement.Inhouse
Oil and GreaseAPHA 5520-B:2017 / IS 3025 Part 39Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
pHAPHA 4500-H+-B / IS 3025 Part 11Measures acidity or alkalinity of the sample under the selected procedure.A result above or below the required range may affect treatment control, corrosion, scaling, process suitability or product conformity.Inhouse
SulphateAPHA 4500-SO4-E / IS 3025 Part 24Quantifies the selected dissolved ion or nutrient-related parameter.A higher or lower result is assessed against the identified water-use requirement and may indicate source, treatment, contamination or process effects.Inhouse
Total AlkalinityAPHA 2320-B / IS 3025 Part 23Reports selected wear, contaminant, additive or composition-related elements.Higher or lower values require comparison with formulation, metallurgy, process inputs and trend history; one result alone does not establish the source.Inhouse
Total Dissolved SolidsAPHA 2540-C / IS 3025 Part 16Assesses ionic or dissolved-material content in water.A higher result generally indicates more dissolved ionic material; significance depends on the water source, treatment and intended use.Inhouse
Total Suspended SolidsAPHA 2540-D / IS 3025 Part 17Assesses suspended material or optical cloudiness in water.A higher result indicates more suspended or light-scattering material and may signal inadequate clarification, contamination or process carryover.Inhouse
TurbidityAPHA 2130-B / IS 3025 Part 10Assesses suspended material or optical cloudiness in water.A higher result indicates more suspended or light-scattering material and may signal inadequate clarification, contamination or process carryover.Inhouse
Biochemical Oxygen DemandIS 3025 Part 44Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
Chemical Oxygen DemandIS 3025 Part 58Assesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse
Microbial ExaminationIS 1622Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
Total and Faecal ColiformIS 5401 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
E. coliIS 5887 Part 1Assesses the selected microbiological indicator or organism group.Detection or a higher count indicates greater microbiological loading; interpretation must follow the applicable water-use requirement and sampling controls.Inhouse
Total Organic CarbonAPHA 23rd Edition 5310BAssesses organic, oxidisable or hydrocarbon-related loading in water.A higher result indicates greater loading under the selected method and may affect treatment, discharge or process suitability.Inhouse

Need a test not shown here?

Ask the laboratory to review your requirement.

Request a QuoteContact Chem-Tech →